H1-06: Terminal S6 Function Selection
No.
Name
(Hex.)
H1-06
Terminal S6 Function
Selection
(0403)
Note:
The default setting is 3 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-07: Terminal S7 Function Selection
No.
Name
(Hex.)
H1-07
Terminal S7 Function
Selection
(0404)
Note:
The default setting is 4 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-08: Terminal S8 Function Selection
No.
Name
(Hex.)
H1-08
Terminal S8 Function
Selection
(0405)
H1-21: Terminal S1 Function Select 2
No.
Name
(Hex.)
H1-21
Terminal S1 Function
Selection 2
(0B70)
When MFDI terminal S1 activates, it will operate the function set to H1-01 [Terminal S1 Function Selection] and
the function set to H1-21 at the same time.
When the setting value is F, the function is disabled.
H1-22: Terminal S2 Function Select 2
No.
Name
(Hex.)
H1-22
Terminal S2 Function
Select 2
(0B71)
When MFDI terminal S2 activates, it will operate the function set to H1-02 [Terminal S2 Function Selection] and
the function set to H1-22 at the same time.
When the setting value is F, the function is disabled.
H1-23: Terminal S3 Function Select 2
No.
Name
(Hex.)
H1-23
Terminal S3 Function
Selection 2
(0B72)
When MFDI terminal S3 activates, it will operate the function set to H1-03 [Terminal S3 Function Selection] and
the function set to H1-23 at the same time.
When the setting value is F, the function is disabled.
H1-24: Terminal S4 Function Selection 2
No.
Name
(Hex.)
H1-24
Terminal S4 Function
Selection 2
(0B73)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDI terminal S6.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDI terminal S7.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDI terminal S8.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S3.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S4.
12.8 H: Terminal Functions
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
4
(0 - 1FF)
Default
(Range)
6
(0 - 1FF)
Default
(Range)
8
(0 - 1FF)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
12
801