12.8 H: Terminal Functions
When MFDI terminal S4 activates, it will operate the function set to H1-04 [Terminal S4 Function Selection] and
the function set to H1-24 at the same time.
When the setting value is F, the function is disabled.
H1-25: Terminal S5 Function Select 2
No.
Name
(Hex.)
H1-25
Terminal S5 Function
Selection 2
(0B74)
When MFDI terminal S5 activates, it will operate the function set to H1-05 [Terminal S5 Function Selection] and
the function set to H1-25 at the same time.
When the setting value is F, the function is disabled.
H1-26: Terminal S6 Function Select 2
No.
Name
(Hex.)
H1-26
Terminal S6 Function
Selection 2
(0B75)
When MFDI terminal S6 activates, it will operate the function set to H1-06 [Terminal S6 Function Selection] and
the function set to H1-26 at the same time.
When the setting value is F, the function is disabled.
H1-27: Terminal S7 Function Select 2
No.
Name
(Hex.)
H1-27
Terminal S7 Function
Selection 2
(0B76)
When MFDI terminal S7 activates, it will operate the function set to H1-07 [Terminal S7 Function Selection] and
the function set to H1-27 at the same time.
When the setting value is F, the function is disabled.
H1-28: Terminal S8 Function Select 2
No.
Name
(Hex.)
H1-28
Terminal S8 Function
Selection 2
(0B77)
When MFDI terminal S8 activates, it will operate the function set to H1-08 [Terminal S8 Function Selection] and
the unction set to H1-28 at the same time.
When the setting value is F, the function is disabled.
MEMOBUS/Modbus MFDI 1 to 3 Function Selection
You can set the function for the MFDI to MEMOBUS register bit 0 to 2 of [15C0(Hex.)]. Use H1-40 to H1-42
[Extend MFDI Function Selection] to select the function.
Note:
• Refer to H1-xx "MFDI setting values" for the setting values of the MFDI.
• You cannot set values 0 [3-Wire Sequence] and 20 to 2F [External Fault] for H1-40 to H1-42.
• When you will not useH1-40 to H1-42, set them to F [Not Used].
• You cannot use MFDI for digital input option DI-A3 at the same time as function selection for MEMOBUS/Modbus MFDI 1 to 3.
H1-40: Mbus Reg 15C0h bit0 Input Func
No.
Name
(Hex.)
H1-40
Mbus Reg 15C0h bit0 Input
Func
(0B54)
802
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S5.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S6.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S7.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for MFDI terminal S8.
V/f
CL-V/f
OLV
CLV
AOLV
Sets MFDI function to set to bit 0 of the MEMOBUS register 15C0 (Hex.).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)

Advertisement

Table of Contents
loading

Table of Contents