10.4 Model-Specific Specifications (400 V Class)
Model
Rated Voltage, Rated Frequency
Permitted Voltage Fluctuation
Permitted Frequency Fluctuation
Power Supply
Input Power (kVA)
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
The maximum applicable motor output complies with 460 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*3
The rated output capacity is calculated with a rated output voltage of 380 V.
*4
The rated output capacity is calculated with a rated output voltage of 460 V.
436
Input Voltage
Duty Rating
HD1
< 460 V
ND1
HD2
≥ 460 V
ND2
4453
4568
• Three-phase AC power supply 380 V to 480 V at 50/60 Hz
• DC power supply 513 V to 679 V
-15% to +10%
±5%
327
370
370
465
335
382
382
429
YASKAWA SIEPC71061705H GA700 Series Technical Manual
4675
465
523
429
476

Advertisement

Table of Contents
loading

Table of Contents