10.2

Drive Duty Modes

The drive has two duty modes from which to select for the application: Heavy Duty (HD) and Normal Duty (ND).
Note:
The drive has two duty modes from which to select for the application: Heavy Duty (HD1/2) and Normal Duty (ND1/2). When E1-01
[Input AC Supply Voltage] ≥ 460 V, the duty rating switches to HD2 or ND2. The specifications listed here are different between HD1
and HD2 and ND1 and ND2.
• The input power kVA
• The maximum applicable motor output
• The rated input current
• The rated output capacity
• The rated output current
The rated output current of HD/ND is the reference to set the parameter as a percentage of the drive rated output
current. Refer to
Table 10.1
E1-01 Setting
Duty Rating
Input Voltage
Heavy Duty Rating 1
• ≥ 200 V and < 240 V
(HD1)
• ≥ 380 V and < 460 V
Heavy Duty Rating 2
≥ 460 V and < 480 V
(HD2)
Normal Duty Rating 1
• ≥ 200 V and < 240 V
(ND1)
• ≥ 380 V and < 460 V
Normal Duty Rating 2
≥ 460 V and < 480 V
(ND2)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
for information about the differences between HD and ND ratings.
Table 10.1 Drive Duty Modes
C6-01
Setting
• Extruder
• Conveyor
0
• Constant torque or high overload
capacity
• Fan
• Pump
1
• Blower
• Variable speed control
Default Carrier
Application
Frequency
2 kHz
2 kHz Swing-PWM

10.2 Drive Duty Modes

Overload Tolerance (oL2
[Drive Overload])
150% of the rated output
current for 60 seconds The
permitted frequency of
overload is one time each 10
minutes.
110% of the rated output
current for 60 seconds The
permitted frequency of
overload is one time each 10
minutes.