YASKAWA GA700 Series Technical Manual page 899

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

L5-04: Interval Method Restart Time
No.
Name
(Hex.)
L5-04
Interval Method Restart
Time
(046C)
L5-05: Auto-Restart Method
No.
Name
(Hex.)
L5-05
Auto-Restart Method
(0467)
0 : Continuous/Immediate Attempts
Counts the number of successful fault resets through Auto Restart.
When this value > L5-01, the drive will send a fault signal and fault code to the keypad and the motor will coast to
stop.
1 : Interval/Attempt after L5-04 sec
Counts the number of all fault resets (successful and unsuccessful) through Auto Restart. The drive repeats the
Auto Restart process in the intervals set in L5-04 [Interval Method Restart Time].
When this value > L5-01, the drive will send a fault signal and fault code to the keypad and the motor will coast to
stop.
L5-07: Fault Reset Enable Select Grp1
No.
Name
(Hex.)
L5-07
Fault Reset Enable Select
Grp1
(0B2A)
0000 : Disabled
0001 : Enabled (—/—/—/oL4)
0010 : Enabled (—/—/oL3/—)
0011 : Enabled (—/—/oL3/oL4)
0100 : Enabled (—/oL2/—/—)
0101 : Enabled (—/oL2/—/oL4)
0110 : Enabled (—/oL2/oL3/—)
0111 : Enabled (—/oL2/oL3/oL4)
1000 : Enabled (oL1/—/—/—)
1001 : Enabled (oL1/—/—/oL4)
1010 : Enabled (oL1/—/oL3/—)
1011 : Enabled (oL1/—/oL3/oL4)
1100 : Enabled (oL1/oL2/—/—)
1101 : Enabled (oL1/oL2/—/oL4)
1110 : Enabled (oL1/oL2/oL3/—)
1111 : Enabled (oL1/oL2/oL3/oL4)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time interval between each Auto Restart attempt. This function is enabled when L5-05 =
1 [Auto Restart Operation Selection = Use L5-04 Time].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the count method for the Auto Restart operation.
V/f
CL-V/f
OLV
CLV
AOLV
Use these 4 digits to set the Auto Restart function for oL1 to oL4. From left to right, the digits set
oL1, oL2, oL3, and oL4, in order.
Figure 12.140 Setting Digits and Fault Code
12.9 L: Protection Functions
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
10.0 s
(0.5 - 600.0 s)
Default
(Range)
0
(0, 1)
Default
(Range)
1111
(0000 - 1111)
12
899

Advertisement

Table of Contents
loading

Table of Contents