T3: Asr And Inertia Tuning; T4: Ez Tuning - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
T2-14
Back-EMF Voltage
Constant (Ke)
(0737)
T2-15
Pull-In Current Level
(0756)
T2-16
Encoder Pulse Count
(PPR)
(0738)
T2-17
Encoder Z-Pulse Offset
(0757)

T3: ASR and Inertia Tuning

No.
Name
(Hex.)
T3-00
Control Loop Tuning
Selection
(1198)
T3-01
Test Signal Frequency
(0760)
T3-02
Test Signal Amplitude
(0761)
T3-03
Motor Inertia
(0762)
T3-04
System Response
Frequency
(0763)

T4: EZ Tuning

No.
Name
(Hex.)
T4-01
EZ Tuning Mode
Selection
(3130)
T4-02
Motor Type Selection
(3131)
T4-04
Motor Rated Revolutions
(3133)
T4-05
Motor Rated Frequency
(3134)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor induced voltage constant (Ke).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level of the pull-in current as a percentage of E5-03 [PM Motor Rated Current
(FLA)]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PG (pulse generator, encoder) pulses.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the encoder Z-pulse offset (Δθ) (pulse generator, encoder) that is listed on the
motor nameplate.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Control Auto-Tuning.
0 : Inertia Tuning
1 : ASR (Speed Regulator)
2 : Deceleration Rate Tuning
3 : KEB Tuning
Note:
Settings 0 and 1 are available only when A1-02 = 3, 7 [Control Method Selection =
CLV, CLV/PM].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of the test signal applied to the motor during Inertia Tuning. Usually
it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amplitude of the test signal applied to the motor during Inertia Tuning. Usually
it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the inertia of the motor. This value uses the test signal response to calculate the
load inertia.
Note:
The display units for the default setting and setting range are different for different
models:
• 0.0001 kgm
2
units (setting range: 0.0001 kgm
4002 to 4012
• 0.001 kgm
2
units (setting range: 0.001 kgm
to 4103
• 0.01 kgm
2
units (setting range: 0.01 kgm
4675
V/f
CL-V/f
OLV
CLV
AOLV
This parameter uses the load inertia value from the Inertia Tuning process to
automatically calculate and set C5-01 [ASR Proportional Gain 1].
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
V/f
CL-V/f
OLV
CLV
AOLV
Sets rated rotation speed (min
-1
) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated frequency (Hz) of the motor.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2
to 6.0000 kgm
2
): 2004 to 2021,
2
to 60.000 kgm
2
): 2030 to 2211, 4018
2
to 600.00 kgm
2
): 2257 to 2415, 4140 to
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
11.16 T: Motor Tuning
Default
Ref.
(Range)
Determined by T2-13
967
(0.0 - 2000.0)
30%
967
(0 - 120%)
1024 ppr
967
(1 - 15000 ppr)
0.0 °
967
(-180.0 - +180.0°)
Default
Ref.
(Range)
0
968
(0 - 3)
3.0 Hz
968
(0.1 - 20.0 Hz)
0.5 rad
968
(0.1 - 10.0 rad)
Determined by o2-04,
968
C6-01, and E5-01
(0.0001 - 600.00 kgm
2
)
10.0 Hz
968
(0.1 - 50.0 Hz)
Default
Ref.
(Range)
0
969
(0, 1)
0
969
(0, 1, 2)
-
969
((40 Hz to 120 Hz) × 60
× 2/E9-08)
Determined by E9-01
969
and o2-04
(40.0 - 120.0 Hz)
575
11

Advertisement