YASKAWA GA700 Series Technical Manual page 588

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

11.17 U: Monitors
No.
Name
(Hex.)
U6-22
ZeroServo Pulse Move
(0062)
U6-25
ASR Output Level
(006B)
Expert
U6-26
Feed Fwd Cont Output
(006C)
Expert
U6-27
FeedFwd Estimate Spd
(006D)
Expert
U6-31
TorqueDetect Monitor
(007B)
U6-36
Comm Errors-Host
(0720)
Expert
U6-37
Comm Errors-Sensor
(0721)
Expert
U6-48
ASIC Comm Errors
(072E)
Expert
U6-57
PolePolarityDeterVal
(07C4)
U6-80
Option IP Address 1
(07B0)
U6-81
Option IP Address 2
(07B1)
U6-82
Option IP Address 3
(07B2)
U6-83
Option IP Address 4
(07B3)
U6-84
Online Subnet 1
(07B4)
U6-85
Online Subnet 2
(07B5)
U6-86
Online Subnet 3
(07B6)
U6-87
Online Subnet 4
(07B7)
U6-88
Online Gateway 1
(07B8)
U6-89
Online Gateway 2
(07B9)
U6-90
Online Gateway 3
(07F0)
U6-91
Online Gateway 4
(07F1)
U6-92
Online Speed
(07F2)
U6-93
Online Duplex
(07F3)
588
V/f
CL-V/f
OLV
CLV
AOLV
Shows the distance that the rotor moved from its last position when Zero Servo is available. The
value shown in this monitor = 4 X [No. of PG pulses].
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the primary delay filter input value of the ASR (speed control loop).
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the Feed Forward control output.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the feed forward estimated speed.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Monitors the torque reference or the output current after applying the filter set to L6-07 [Torque
Detection Filter Time].
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of inter-CPU communication errors. When you de-energize the drive, this
value resets to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of inter-CPU communication errors. When you de-energize the drive, this
value resets to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of inter-ASIC communication errors detected by the ASIC. When you de-
energize the drive, this value resets to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the change from the integrated current when the drive finds the polarity.
Unit: 1
Note:
If the change from the integrated current is less than 819, increase n8-84 [Polarity Detection
Current]. U6-57 = 8192 is equivalent to the motor rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available local IP Address (1st octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available local IP Address (2nd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available local IP Address (3rd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available local IP Address (4th octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available subnet mask (1st octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available subnet mask (2nd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available subnet mask (3rd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available subnet mask (4th octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available Gateway address (1st octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available Gateway address (2nd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available Gateway address (3rd octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available Gateway address (4th octet).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available communications speed.
10: 10 Mbps
100: 100 Mbps
V/f
CL-V/f
OLV
CLV
AOLV
Shows the currently available Duplex setting.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
MFAO Signal Level
10 V = Number of pulses
per revolution (-10 V to +10
V)
10 V = Motor secondary
rated current (-10 V to +10
V)
10 V = Motor secondary
rated current (-10 V to +10
V)
10 V = Maximum
frequency
(-10 V to +10 V)
10 V:100%
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available

Advertisement

Table of Contents
loading

Table of Contents