12.8 H: Terminal Functions
Note:
When you use L7-01 to L7-04 and analog inputs to set torque limits for the same quadrant, it will enable the lower torque limit.
13: Torque Reference / Torque Limit
Setting Value
Function
13
Torque Reference / Torque
Limit
Note:
When you use L7-01 to L7-04 and analog inputs to set torque limits for the same quadrant, it will enable the lower torque limit.
14: Torque Compensation
Setting Value
Function
14
Torque Compensation
15: General Torque Limit
Setting Value
Function
15
General Torque Limit
16: Differential PID Feedback
Setting Value
Function
16
Differential PID Feedback
The drive uses the deviation between the PID feedback and the differential feedback value signals to calculate the
PID input.
1F: Not Used
Setting Value
Function
1F
Not Used
When you set a terminal that you do not use to 1F, you can use the signal that is input to that terminal as the PLC
analog signal input from MEMOBUS/Modbus communications or the communication option. This input signal
does not have an effect on drive operation. This signal functions the same as F (Through Mode).
30: DWEZ Analog Input 1
Setting Value
Function
30
DWEZ Analog Input 1
31: DWEZ Analog Input 2
Setting Value
Function
31
DWEZ Analog Input 2
32: DWEZ Analog Input 3
Setting Value
Function
32
DWEZ Analog Input 3

H4: Analog Outputs

H4 parameters set the drive analog monitors. These parameters select monitor parameters, adjust gain and bias,
and select output signal levels.
856
V/f
CL-V/f
OLV
CLV
AOLV
Enters the torque reference if the motor rated torque is 100%. This setting is the torque limit for speed control.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the torque compensation value if the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the torque limit that is the same for all quadrants for forward, reverse, and regenerative operation if the motor rated
torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the PID differential feedback value if the full scale analog signal (10 V or 20 mA) is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting for unused terminals or to use terminals in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual