10.3 Model-Specific Specifications (200 V Class)
Model
Rated Output
Capacity (kVA)
Rated Output
Current (A)
Overload Tolerance
Output
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency
Measures for
DC reactor
Harmonics
Braking Device
Braking Transistor
EMC Filter
EMC Filter
IEC61800-3, C3
Rated Voltage, Rated Frequency
Permitted Voltage Fluctuation
Power Supply
Permitted Frequency Fluctuation
Input Power
(kVA)
*1
The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*2
The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*3
The rated output capacity is calculated with a rated output voltage of 208 V.
*4
The rated output capacity is calculated with a rated output voltage of 220 V.
430
2169
*3
HD1
55.3
*4
ND1
64.4
HD1
145
ND1
169
• HD: 150% of the rated output current for 60 seconds The permitted frequency of overload is one time each 10
minutes.
• ND: 110% of the rated output current for 60 seconds The permitted frequency of overload is one time each 10
minutes.
Note:
Derating can be necessary for applications that start and stop frequently.
HD: 5 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 10 kHz maximum.
Three-phase 200 V to 240 V
Note:
The maximum output voltage is proportional to the input voltage.
• AOLV and EZOLV: 120 Hz
• CL-V/f, CLV, AOLV/PM, and CLV/PM: 400 Hz
• V/f, OLV, OLV/PM: 590 Hz
Standard internal characteristics
External options
Factory option
• Models 2xxxB: There is a category C3 EMC filter in the drive.
• Three-phase AC power supply 200 V to 240 V at 50/60 Hz 
• DC power supply 270 V to 340 V
-15% to +10%
±5%
HD1
56.5
ND1
68.2
2211
2257
68.6
81.9
80.4
97.9
180
215
211
257
68.2
83.1
83.1
113
YASKAWA SIEPC71061705H GA700 Series Technical Manual
2313
2360
108
132
119
137
283
346
313
360
113
135
135
164
2415
158
 
415
-
164
-

Advertisement