YASKAWA GA700 Series Technical Manual page 401

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

A - Front of drive
B - Insertion area
5.
Push the hooks on the back side of the fan finger guards and click them into place on the drive.
6.
Energize the drive and set o4-03 = 0 [Fan Operation Time Setting = 0 h] to reset the fan operation time.
Circulation Fan Removal
Remove the drive cover before you start this procedure.
CAUTION! Crush Hazard. Loosen the cover screws. Do not fully remove them. If you fully remove the cover screws, the
terminal cover can fall and cause moderate injury.
YASKAWA SIEPC71061705H GA700 Series Technical Manual
C - Connector tab
Figure 8.38 Reattach the Fan Finger Guards
Figure 8.39 Reattach the Fan Finger Guards
8.4 Replace Cooling Fans and Circulation Fans