Scaling function control

This parameter enables / disables the Scaling function. When this
parameter is disabled, the device uses the hardware singleturn and
multiturn resolutions; when it is enabled, the device uses the
resolutions set next to the parameters
and
Total measuring range.
function parameters"on page 67.
Attribute
Meaning
Disable
Scaling function disabled
Enable
Scaling function enabled
NOTE
There is no functionality of this parameter if the
functionality
parameter is disabled.
Alarm channel control
This parameter enables / disables the encoder specific Alarm
channel transferred as Channel Related Diagnosis. This functionality
is used to limit the amount of data sent in isochronous mode.
If the value is zero (0 = default value), only the communication
related alarms are sent via the alarm channel. If the value is one (1),
also the encoder specific faults and warnings are sent via the alarm
channel.
For further information refer also to the section "10.2 Error messages
via the Alarm Channel".
Attribute
Meaning
Disable
No profile specific diagnosis
Enable
Profile specific diagnosis
NOTE
This parameter is only supported in compatibility mode (see
Compatibility mode
Measuring units / Revolution
Refer also to the section "Scaling
on page 67).
AMT58x-PN ProfiNET®
Value
0
1
Class 4
Value
0
1
61