Chapter 2

2.3 Scanning System

2.3.1 When Replacing the
Scanning
Standard White Plate,
Lamp
Reflecting Lamp Cover,
Reader Controller PCB,
Flash memory on Reader
controller
PCB,
Analog Processor PCB
CCD Unit
CLC5100 / CLC4000
1) Execute data reading using 'CCD' under 'FUNC' in
service mode.
2.3.2 Routing the Scanner
Cable
CLC5100 / CLC4000
You must keep the mirror positioning tool (FY9
3040 000) near at hand before routing the scanner
cable.
1) Remove the left cover and the hopper left cover.
2) Remove the control panel.
3) Remove the vertical size plate and the right glass
retainer right, and remove the copyboard glass.
4) Move the No. 2 mirror mount until the pulley shaft
[1] of the No. 2 mirror mount is visible through the
long hole [2] in the side plate.
2-12
Lamp,
Regulator,
or
0002-5743
0002-6049
[2]
F-2-20
[1]
F-2-21
5) Fit a binding screw (M4 × 8mm) [3] to the pulley
shaft [4] to fix the front and rear of the pulley
temporarily to the side plate [5], thereby
temporarily fixing the No. 2 mirror mount in place.
[5]
[4]
[3]
F-2-22
[1]
[2]
[3]
[4]
[5]