2
Technology > MEAP > Option for exclusive individual measure > Setting of Screen Transition from MEAP Screen to the Standard Screen (level2)
■
Setting of Screen Transition from MEAP Screen to the Standard
Screen (level2)
In the case that the operation is restricted by MEAP application, make a setting to hide Native
applications such as Copy/Send/Box. With this setting, disable screen transition with => key.
Default value
0: OFF (transit to Native screen)
Setting range, item
0: OFF (transit to Native screen) 1: ON (No-transition to Native screen)
●
Setting Procedure
1) Startup [SERVICE MODE] (After pressing [USER MODE] button of MEAP device, press [2]
button and [8] button at the same time on control panel. Then, by pressing [USER MODE]
button again, [SERVICE MODE] screen is displayed).
2) Startup level 2 of [SERVICE MODE] (After starting up [SERVICE MODE] in step 1, press
[USER MODE] button again. Then, by pressing [2] button on control panel, the screen is
displayed.
3) Press [COPIER] button.
4) Press [Option] button.
5) Press [DSPLY-SW] button.
6) Press
or
(arrow) button.
7) Press [MEAP-DSP] button.
8) Press either 0 (transit to Native screen) or 1 (no-transition to Native screen) on control
panel (the numerical value input in the field is displayed), and press [OK] button.
9) Check to see that it is reflected in setting field, and restart the device.
2
Technology > MEAP > Option for exclusive individual measure > Setting of Screen Transition from MEAP Screen to the Standard Screen (level2)
2-218
2-218