No Snmp View - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network protocols
7.4 SNMP
Further notes
You delete the view with the
You display the configured view trees with the
You display the SNMP group access rights with the
You configure the SNMP group access rights with the
7.4.2.23

no snmp view

Description
With this command, you delete an SNMP view.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp view <ViewName><OIDTree>
The parameters have the following meaning:
Parameter
ViewName
OIDTree
Result
The SNMP view is deleted.
Further notes
You configure a view with the
You display the configured view trees with the
352
command.
no snmp view
show snmp viewtree
Description
Name of the view
Object ID
command.
snmp view
show snmp viewtree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
command.
show snmp group access
command.
snmp access
Range of values / note
max. 32 characters
Path information of the MIB tree
command.
Configuration Manual, 10/2015, C79000-G8976-C351-05