Network protocols
7.4 SNMP
Syntax
Call up the command with the following parameters:
snmp targetaddr <TargetAddressName> param <ParamName>
The parameters have the following meaning:
Parameter
TargetAddressName
param
ParamName
ipv4
IPAddress
fqdn-name
FQDN
timeout
Seconds
retries
RetryCount
taglist
TagIdentifier
none
volatile
nonvolatile
port
integer
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 25)".
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target address is configured.
344
{ipv4 <IPAddress> | fqdn-name <FQDN>}
[timeout <Seconds(1-1500)] [retries <RetryCount(1-3)]
[taglist <TagIdentifier | none>] [{volatile | nonvolatile}]
[port <integer (1-65535)>]
Description
Name of the target address
Keyword for the parameter name
Name of the parameter
Keyword for an IPv4 address
IPv4 address
Keyword for a domain name
Domain name (Fully Qualified Do-
main Name)
Keyword for the time the SNMP
agent waits for a response before it
repeats the inform request message
Time in seconds
Keyword for the maximum number of
attempts to obtain a response to an
inform request message
Number of attempts
Keyword for tag list
Tag identifier that selects the desti-
nation address for SNMP.
No tag identifier
Specifies whether the settings re-
main following a restart.
Keyword for the port number at
which the SNMP manager receives
traps and inform messages
Port number
Range of values / note
Maximum of 32 characters
-
Maximum of 32 characters
-
Enter a valid IPv4 unicast address.
-
Maximum of 100 characters
-
1 ... 1500
-
1 ... 3
-
Specify the tag identifier.
-
-
1 ... 65535
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
:
volatile
The default settings are used af-
ter a restart.
:
nonvolatile
The saved settings are used af-
ter a restart.

Hide quick links: