The parameters have the following meaning:
Parameter
interface-type
interface-id
description
status
vlan
vlan-id
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
If you do not select any parameters from the parameter list, the status and configuration of
all available interfaces will be displayed.
Result
The status and the configuration of the selected interfaces are displayed.
3.1.1.7
show interfaces ... counters
Description
This command shows the counters of one, several or all interfaces.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:

show interfaces

[{<interface-type><interface-id>]|{vlan<vlan-id(1-4094)>}]counters
The parameters have the following meaning:
Parameter
interface-type
interface-id
vlan
vlan-id
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Type or speed of the interface
Module no. and port no. of the interface
Shows the description of the interface
Shows the status of the interface
Keyword for a VLAN connection
Number of the addressed VLAN
or
cli#
Description
Type or speed of the interface
Module no. and port no. of the interface
Keyword for a VLAN connection
Number of the addressed VLAN
Configuration
3.1 System
Range of values / note
Enter a valid interface.
-
-
-
1 ... 4094
Range of values / note
Enter a valid interface.
-
1 ... 4094