Call up the command with the following parameters:
spanning-tree mst{instance-id<instance-id(1-64)>}root{primary|secondary}
The parameters have the following meaning:
Parameter
instance-id
instance-id
primary
secondary
Result
The function of the device is specified.
Further notes
You disable the root bridge with the
You display this setting and other information with the commands that start with
spanning tree ...
6.3.3.11

no spanning-tree mst instance-id root

Description
With this command, you disable the "root bridge" function on the device.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Keyword for the instance
Number of the instance
The priority of the device is set to a low value so that the
device can become the root bridge (primary) of the
Spanning Tree instance. The lower the value, the higher
the priority.
The priority of the device is set to a low value so that the
device becomes the substitute root bridge (secondary)
of the Spanning Tree instance. If the root bridge (prima-
ry) fails, the substitute root bridge (secondary) takes
over the task of the root bridge without delay.
no spanning-tree mst instance-id root
.
Network structures
6.3 Spanning Tree
Range of values / note
-
1 ... 64
The priority is set to the
value 24576.
The priority is set to the
value 28672.
command.