The parameter has the following meaning:
Parameter
frames
Result
The number of frames is specified.
Further notes
You display the setting with the
6.1.5.9

wlan amsdu

Description
With this command, you enable the sending of A-MSDU data packets. Several MSDUs with
the same destination address are bundled into an A-MSDU and are sent together. This
reduces the network load. The function is enabled as default.
Requirement
● The IEEE 802.11n transmission standard is enabled.
● You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan amsdu
Result
The sending of A-MSDU data packets is enabled.
Further notes
You display the setting with the
You disable the function with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Number of frames that are grouped to-
gether in one AMPDU data packet.
show wlan advanced-11n <wlan 0/X>
show wlan advanced-11n <wlan 0/X>
no wlan amsdu
Range of values / note
2...64
Default: 32
command.
command.
command.