Siemens SIMATIC NET Configuration Manual page 266

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network structures
6.3 Spanning Tree
Parameter
link-type
portfast
port-priority
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
Further notes
You can reset the setting to the default with the
You display these settings and other information with the commands that start with
spanning tree ...
266
Description
Connection status of the following
network segment
Enables the PortFast function
Priority of the interface
.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
point-to-point
shared
Default:
point-to-point
The connection is configured
as
full-duplex
shared
in all other cases
-
Default: disabled
0 ... 240 in steps of 16
Default: 128
(properties) command.
no spanning-tree
Configuration Manual, 10/2015, C79000-G8976-C351-05
show

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents