No Vap Communication With Ethernet (Access Point); Management Access Control List - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Security and authentication

10.3 Management Access Control List

10.2.5.11

no vap communication with ethernet (access point)

Description
With this command, you specify that the client cannot communicate via the Ethernet
interface.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with ethernet
Result
The communication option is disabled.
Further notes
You display the settings with the
You enable the function with the
See also
vap communication with ethernet (access point) (Page 427)
10.3
Management Access Control List
This section describes the commands relevant for working with the management access
control list.
428
show wlan security <vapX 0/Y>
vap communication with ethernet
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.
command.