Siemens SIMATIC NET Configuration Manual page 448

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Diagnostics
11.1 Diagnostics
Syntax
Call up the command with the following parameters:
no event config
{cold-warmstart|linkchange|authentication-failure|
The parameters have the following meaning:
Parameter
cold-warmstart
linkchange
authentication-failure
power-change
faultstate-change
stp-change
overlap-ap
wds
dfs
wlan-general
wlan-auth-log
ipcf-cycle-time
ipcf-poll-size
all
logtable
syslog
email
trap
faults
all
Result
The setting deciding which messages of the device are not stored or sent is configured.
Further notes
You display the status of the events and the clients with the
You configure which of the various message types of the device will be stored or forwarded
with the
448
power-change|faultstate-change|stp-change|
overlap-ap|wds|dfs|wlan-general|
wlan-auth-log|all}{logtable|syslog|email|trap|faults|all}
Description
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when there is a change in the Spanning Tree
Message if radio channels overlap (in Access Point mode only)
Message if there are changes to WDS (in Access Point mode only)
Message if a radar signal is received or if there is a status change in the DFS scan
(only in Access Point mode)
Message if the channel bandwidth has changed (in Access Point mode only)
Message if changes are made to the log file (in Client mode only)
Message if too many clients are logged on for the set iPCF cycle time or if some cli-
ents were not reached in one cycle
(only in access point mode and only available if supported by the device)
Message when the PNIO data size is too large for the transmission.
(only available if supported by the device)
All messages
Client that processes the logbook entries
Client that sends the messages to the log server
Client that sends the e-mails
Client that sends the SNMP traps
The device triggers an error. The error LED lights up.
All clients at once
command.
event config
show events config
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents