Password - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Configuration
3.2 Load and Save
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp server {ipv4 <ucast-addr> | fqdn-name <FQDN>} [port<tcp port(1-65535)>]
The parameters have the following meaning:
Parameter
ipv4
ucast-addr
fqdn-name
FQDN
port
tcp port
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The settings for the access to the selected TFTP server are configured.
3.2.5.6

password

Description
With this command, you activate and configure the password for encrypted certificates.
User, server or HTTPS certificates can exist as PKCS#12 certificates (.p12 and .pfx) and
PEM certificates (.pem).
Note
User and server certificate in one file
If the user and the server certificate are located in the same file, load this file on the device
as the user certificate and as the server certificate.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
78
Description
Keyword for an IPv4 address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for the port of the server via
which the TFTP connection runs
Number of the port
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
-
Enter a valid IPv4 unicast ad-
dress.
-
Maximum 100 characters
-
1 ... 65535
Configuration Manual, 10/2015, C79000-G8976-C351-05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents