Dcp Server - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network protocols
7.1 IPv4 protocol
Syntax
Call up the command with the following parameters:
no ip route <gateway>
The parameter has the following meaning:
Parameter
gateway
Result
The entry is deleted.
Further notes
You configure an entry from the IP routing table with the
You display the IP routing table with the
7.1.2.7

dcp server

Description
With this command, you configure the read and write permissions for the DCP server and
enable it.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
dcp server {read-only|read-write}
The parameters have the following meaning:
Parameter
read-only
read-write
Result
The read and write permissions for the DPC server are configured.
The DCP server is enabled.
Further notes
You disable the DCP server with the
290
Description
Specifies the IP address of the gateway.
Description
only reading is permitted on the DCP
server
reading and writing is permitted on the
DPC server
ip route
command.
show ip route
command.
no dcp server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Range of values / note
Specify a valid IP address.
command.
Range of values / note
-
Default:
read-write

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents