No Authorized-Manager Ip-Source - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

If optional parameters are not specified when configuring, the following defaults apply:
● The manager is authorized for all services.
Note
Configuration of the first entry
As long as the list of authorized managers is empty, access to the system is not
restricted.
As soon as the list contains an entry, access to the system is blocked for all others.
You should therefore configure the interface via which you access the system first
because your access is otherwise blocked.
Result
The interfaces and protocols via which an authorized manager is allowed to access the
device are configured.
Further notes
You delete an interface for access of an authorized manager with the
ip-source
You show the information about the configuration of the authorized managers with the
authorized-manager
10.3.2.2

no authorized-manager ip-source

Description
With this command, you delete an interface via which an authorized manager is allowed to
access the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no authorized-manager ip-source <ip-address>
[{<subnet-mask>|/<prefixlength(0-32)>}]
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.
command.
Security and authentication
10.3 Management Access Control List
no authorized-manager
show