No Spanning-Tree Priority - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

6.3.3.15

no spanning-tree priority

Description
With this command, you reset the priority of the device back to the default value.
The default value is 32768.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree[mst <instance-id(1-64)>]priority
The parameters have the following meaning:
Parameter
mst
instance-id
Result
The priority of the device is reset to the default value.
Further notes
You configure the setting with the
You display this setting and other information with the commands that start with
spanning-tree ...
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Keyword for a Multiple Spanning Tree
instance
Number of the instance
spanning-tree priority
.
Network structures
6.3 Spanning Tree
Range of values / note
-
1 ... 64
command.
show
261

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents