Base Bridge-Mode - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

6.2.2.5

base bridge-mode

Description
With this command, you configure whether or not the device is configured as a bridge
according to IEEE 802.1D for the Spanning Tree protocol or according to IEEE 802.1Q for a
virtual bridged LAN.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
base bridge-mode {dot1d-bridge|dot1q-vlan}
The parameters have the following meaning:
Parameter
dot1d-bridge
dot1q-vlan
Result
The device mode is configured.
Further notes
You display the status of this function and other information with the
command.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Sets the mode of the device to "transparent"
for the Spanning Tree protocol.
sets the mode of the device to "VLAN-aware"
for a virtual bridged LAN.
Network structures
6.2 VLAN
Range of values / note
Default setting
-
show vlan device info
227

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents