7.3.3.9

set-interface

Note
The command is only available with the following device:
• SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
• SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command, you specify the interface via which the IPv4 addresses are dynamically
assigned.
The requirement for the assignment is that the IPv4 address of the interface is located within
the IPv4 address band. If this is not the case, the interface does not assign any IPv4
addresses.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
set-interface {vlan <vlan-id (1-4094)> | <interface-type> <interface-id> }
The parameters have the following meaning:
Parameter
vlan
vlan-id
interface-type
interface-id
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The interface is assigned. Before the IPv4 address band can be used, it still needs to be
activated.
Further notes
You display the setting with the
You enable the IPv4 address band with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Keyword for a VLAN connection.
Number of the
addressed VLAN
Type or speed of the interface
Module no. and port no. of the interface
show ip dhcp-server pools
pool-enable
Network protocols
7.3 DHCP server
Range of values / note
-
1 ... 4094
Enter a valid interface
command.
command.