The parameters have the following meaning:
Parameter
off
on
Result
PNIO is enabled or disabled after the next restart.
Further notes
You display the current PNIO configuration with the
3.1.9.10

system contact

Description
With this command, you enter contact information for the system.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
system contact <string>
The parameter has the following meaning:
Parameter
string
Result
The contact information is created in the system.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
PNIO is deactivated.
PNIO is activated.
Description
Input box for contact information
Range of values / note
If a PROFINET connection is established; in
other words the PNIO AR status is "Online",
you cannot disable PNIO.
When PNIO is turned on, EtherNet/IP is
turned off. The switchover from PNIO and
EtherNet/IP has no effect on DCP.
command.
show pnio
Range of values / note
max. 255 characters
Configuration
3.1 System
57