Result
The status of the signal recorder and the recording are displayed.
● If the recording has started, the configured interval and the current number of recorded
measured values are displayed.
● If the recording has stopped, the configured interval and the number of recorded
measured values are displayed.
4.2.2

wlan signal-recorder start (client)

Description
With this command, you configure and start recording with the signal recorder. The recorded
measured values are saved every 10 minutes and logged in files. On completion of the
recording, the files can be downloaded as a zip file using http or tftp.
The automatic saving contains only the last fully elapsed 10 minutes. The remaining minutes
are discarded.
If the signal recorder is ended manually or if the procedure was ended automatically, the file
contains all the values since the start of the recording.
If a recording is interrupted before 10 minutes have elapsed (e.g. due to a restart or power
down), no signal recorder file is saved.
Note
This command is only available in the client mode.
Requirement
● The WLAN interface is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (1 - 60000)> <sample_number(1 - 20000)> start
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
or
cli#
Functions specific to SCALANCE
4.2 Signal recorder