Network structures
6.1 WLAN
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
show wlan available-ap-list <wlan 0/X> [connected]
The parameters have the following meaning:
Parameter
wlan 0/X
connected
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The access points to which the client can set up a wireless link are displayed.
6.1.1.7

show wlan basic

Description
This command displays the WLAN-basic configuration, for example, transmission standard,
frequency band.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
136
or
cli#
Description
WLAN interface
shows the information of the access points
with which the client is connected.
or
cli#
Range of values / note
Enter a valid interface.
-