4.2 Signal recorder
The parameter has the following meaning:
Parameter
wlan 0/X
ms
sample_number
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The recording is configured and will be started. The measured values are logged in files. If
these files already exist, they will be overwritten. If the set total number of measured values
is reached, the recording stops automatically. Use the
stop
Further notes
You stop the recording early with the
You display the status of the signal recorder and the recording with the
recorder <wlan 0/X>
4.2.3

wlan signal-recorder stop (client)

Description
With this command, you stop the recording with the signal recorder.
Note
This command is only available in the client mode.
Requirement
● A recording was started.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
96
Description
WLAN interface
The interval in milliseconds (ms) be-
tween acquisition of two measured
values
This parameter specifies how many
measured values will be recorded.
command to stop the recording early.
command.
or
cli#
Range of values / note
Enter a valid interface.
1 - 60000
1 - 20000
wlan signal-recorder <wlan 0/X>
wlan signal-recorder <wlan 0/X> stop