Siemens SIMATIC NET Configuration Manual page 272

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network structures
6.3 Spanning Tree
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree mst<instance-id(1-64)>
The parameters have the following meaning:
Parameter
instance-id
cost
port-priority
disable
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
Further notes
You can reset the setting to the default with the
You display these settings and other information with the commands that start with
spanning tree ...
272
{cost(0-200000000)|port-priority (0-240)|disable}
Description
Number of the addressed instance
Costs of the port for calculating the
lowest cost path.
Priority of the interface
disables the interface for multiple
spanning tree
.
Range of values / note
1 ... 64
0 ... 200000000
Default:
0 ... 240 in steps of 16
Default: 128
-
Default:
The Multiple Spanning Tree func-
tion is enabled on the interface
no spanning-tree mst
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
200000 for physical interfaces
199999 for port channels
(properties) command.