4.4.2.4

wlan ipcf-mc mgmt-scan-period (client)

Note
The command is only available with the following device:
• SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
Description
With this command, you the time for the background scan interval as a multiple of the update
time.
Requirement
The SCALANCE W700 device is in client mode
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc mgmt-scan-period <num-of-cycles (1-10)>
The parameter has the following meaning:
Parameter
num-of-cycles
Result
The time is set.
Further notes
You display the setting with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Duration
show wlan ipcf-mc
Functions specific to SCALANCE
Range of values / note
1 ... 10
command.
4.4 iPCF-MC