Result
The time is configured.
Further notes
You display the setting with the
7.3.3.2

network

Note
The command is only available with the following device:
• SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
• SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command you configure the IPv4 address band from which the DHCP client
receives any IPv4 address.
Note
Maximum number of IP addresses
The maximum number of IPv4 addresses that the DHCP server supports is 100. In other
words, a total of 100 IPv4 addresses (dynamic + static).
With the static assignments, you can create a maximum of 20 entries.
Assignment of IP addresses
The requirement for the assignment is that the IPv4 address of the interface is located within
the IPv4 address band. If this is not the case, the interface does not assign any IPv4
addresses
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
network <lower-IP> <upper-IP> { <subnet-mask> | / <prefix-length (0-32)> }
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
show ip dhcp-server pools
Network protocols
7.3 DHCP server
command.