Diagnostics
11.1 Diagnostics
Syntax
Call the command without parameters:
show logbook
or
Call up the command with the following parameters:
show logbook { info | warning | critical }
The parameters have the following meaning:
Parameter
info
warning
critical
Result
The content of the logbook is displayed.
11.1.1.8

show power-line-state

Description
This command shows the status of the power supply.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
show power-line-state
Result
The status of the power supply is displayed.
438
Description
All log entries of the categories "Information", "Warning" and "Critical" are
displayed.
All log entries of the categories "Warning" and "Critical" are displayed.
All log entries of the category "Critical" are displayed.