No Wlan Amsdu - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network structures
6.1 WLAN
6.1.5.10

no wlan amsdu

Description
With this command, you disable the sending of A-MSDU data packets. If the function is
disabled, only A-MSDU data packets can be received.
Requirement
● The IEEE 802.11n transmission standard is enabled.
● You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan amsdu
Result
The sending of A-MSDU data packets is disabled.
Further notes
You display the setting with the
You enable the function with the
164
show wlan advanced-11n <wlan 0/X>
command (default setting).
wlan ampsu
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.