Measurement Parameters (Scan Edge Width) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

2
Place a check at "Edge color
specification" in the "Color setting" area.
3
This item selects the color to be detected as edges.
Setting methods
Image Display area
Color chart
R, G, B
Difference R, G, B
Detection mode

Measurement Parameters (Scan Edge Width)

Measurement parameters can be changed as needed to address unstable measurement results. Normally, the
factory default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
measurement.
1
In the Item Tab area, click [Measurement].
The edge profile of the measurement region is displayed as a graph in the Image Display area.
Detected edge
Measurement
region (white)
Divided measurement
region (green)
Edge level
Color difference
distribution
FH/FZ5 Processing Item Function Reference Manual
Specify a region on the image that includes the target color. The average color of the
specified region is registered.
Click the reference color on the color chart to specify it. The RGB values for the
specified color are displayed at the bottom.
The color to be detected is set with the RGB values.
This sets the allowable color difference for detecting the edge, using the specified color
as the reference. The larger the difference values, the larger the color range that is used
to detect the edge.
Color IN: The position where a color other than the specified color changes to the
specified color is detected as the edge.
Color OUT: The position where the specified color changes to a color other than the
specified color is detected as the edge.
Start
End
point
point
For "Color IN" edge
measurement mode
Description
Start
End
point
point
For "Color OUT" edge
measurement mode
2