Output Parameters (Color Data); Key Points For Test Measurement And Adjustment (Color Data) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

For monochrome cameras
1
When the setting has been changed, click [Measurement] to verify whether measurements
can be made correctly.
2
Set up the judgement condition.
Setting item
Density average
Density deviation

Output Parameters (Color Data)

Specifies whether or not the judgement results of this processing unit is reflected in the scene overall judgement.
1
Click [Output parameter] in the Item Tab area.
2
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Color Data)

The following content can be confirmed in the "Detail result" area using text.
For color cameras
Displayed items
Judge
Average R
Average G
Average B
Color difference
Color deviation
H average
S average
V average
For monochrome cameras
Displayed items
Judge
Density average
Density deviation
FH/FZ5 Processing Item Function Reference Manual
Setting value
Specify the upper and lower limit values for judging the average density of
0 to 255
the measurement region.
Specify the upper and lower limit values for the deviation of the average
0 to 127
density in the measurement region.
Set value
[Factory default]
• [ON]
Enables choosing whether or not the judgement results of this processing
• OFF
unit is reflected in the scene overall judgement.
Judgement result
R (red) element average value
G (green) element average value
B (blue) element average value
The color difference between the average color and reference color in the measurement region
Color deviation in the measurement region
Average H (Hue) component value
Average S (Saturation) component value
Average V (Value) component value
Judgement result
Difference between the average density and the reference density in the measurement region
Density deviation in the measurement region
Description
Description
Description
Description
2
313
Color Data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents