Omron FH-3 Series Reference Manual page 31

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

2
In the "Frame/Field" area, select either "Frame" or "Field".
Item
[Factory default]
[Frame]
Frame/Field
Field
Number of lines to be read
By narrowing the image range to be loaded, the image
scan time can be shortened.
Set the range taking the offset of the measurement
object into consideration.
The part of the image narrowed down by the start line
and the end line will be displayed in the Image Display
area of the processing item setting window or the Main
screen.
Note
About minimum number of lines
• The minimum number of lines (minimum number of lines between start and end lines) is 12 lines.2043
• For 5 megapixel cameras, the end line is fixed from 1921 to 2043.
About coordinate values
• The coordinate values displayed as the measurement results are the values of the display position on the monitor.
• The coordinate values do not vary according to the settings for "Number of lines to be read".
1
In the Item Tab area, click [Camera
setting].
2
Set the start/end line in the "Number of
lines to be read" area.
Important
• When the built-in lighting of an FZ-SQ is used, it may not be possible to shorten the processing time due to
restrictions on the light emission time.
FH/FZ5 Processing Item Function Reference Manual
Set value
Measurements are done in frame units.
Measurements are done in field units. Select "Field" when you prefer shorter
image input time rather than higher accuracy.
Processing becomes faster since each image is scanned skipping one scan
line per two consecutive lines, but the measurement precision is decreased
because the vertical image resolution is lower.
Description
Start line
End line
Camera Image Input
1
Image range
to be scanned
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents