Setting item
Use timeout
Setting time
Unit judgement in timeout
Important
• Normally the "Use timeout" check box should be selected. When the check mark is removed from "Use timeout",
the wait state can only be cleared by executing a "Wait state clear command" from an external device.
3
In the "DO Signal Setting" area, specify a value for each item.
Setting item
Wait signal
Signal No.
FLG signal
Signal No.
Note
• If the same signal is set for the WAIT signal and the FLG signal, a "Same Signals are Assigned" error message
will appear. Assign different signals for each.
854
Control Flow Parallel
Setting value
[Factory default]
If you want to clear the measurement flow wait state
after a certain period of time elapses, select the "Use
• [Checked]
timeout" check box.
• Unchecked
This should normally be used with the check box
selected.
This item can be set when the [Use timeout] check box
is selected.
Set the time in ms after which the wait state on the
processing unit is cleared.
0 to 120,000
When a timeout is used, the wait state is cleared when
[5,000]
the time set in "Setting time" elapses after the
measurement unit starts measurement processing.
When the wait state is cleared, the measurement flow
resumes.
This item can be set when the [Use timeout] check box
is selected.
• [NG]
Select whether the judgement result of the processing
• OK
unit is NG or OK when the processing unit times out
after the "Setting time" in measurement processing.
Setting value
[Factory default]
• [Checked]
• Unchecked
DO0 to DO15
[DO0]
• [Checked]
• Unchecked
DO0 to DO15
[DO1]
FH/FZ5 Processing Item Function Reference Manual
Description
Description
To use a DO signal as a Flow Command Wait
signal, select the "WAIT signal" (a signal
indicating that a command is available during a
flow) checkbox.
This should normally be used with the check box
selected.
Set the signal that is used as a WAIT signal.
The signal set here can be used as a Flow
Command Wait signal.
To use a DO signal as a Flow Command
Completion signal, select the "FLG signal" (a
signal indicating a flow command completion)
checkbox.
This should normally be used with the check box
selected.
Set the signal that is used as the FLG signal.
The signal set here can be used as a Flow
Command Completion signal.