Setting item
Defect pos X -99999.9999 to 99999.9999
Defect pos Y -99999.9999 to 99999.9999
Note
• Defect coordinates give the center of gravity position of detected defects.

Output Parameters (Fine Matching)

Specify how to treat the coordinates to be output to the external device as measurement results. This item can
be changed if necessary. Normally, the factory default value will be used.
Important
• After setting up the measurement parameters, changing the output parameters will cause measurement results to vary
accordingly. If the output parameters have been changed, re-specify the measurement, too.
1
Click [Output parameter] in the Item Tab area.
2
Specify each of the following items.
Setting item
Output coordinates
Calibration
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Fine Matching)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Quantity
Area
Defect coordinate X
Defect coordinate Y
The image specified in the Sub-image number in image display setting is displayed in the Image Display area.
Sub image number.
0
1
FH/FZ5 Processing Item Function Reference Manual
Set value
Set value
[Factory default]
• [After scroll]
As measurement results, select whether to output coordinate values to
• Before scroll
external devices before or after the position compensation is applied.
Select whether to reflect the calibration in the values output to the
• [OFF]
external device as measurement results.
• ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
• [ON]
Enables choosing whether or not the judgement results of this processing
• OFF
unit is reflected in the scene overall judgement.
Judgement result
Number of defects
Defect area
Defect coordinate X
Defect coordinate Y
Explanation of image to be displayed
Measurement image
Difference image display
Description
Specify the X and Y axis move ranges for the center of gravity
positions that are judged to be OK.
When the "Labeling" is used, the center of gravity position of
the label number will be specified instead.
Specify the X and Y axis move ranges for the center of gravity
positions that are judged to be OK.
When the "Labeling" is used, the center of gravity position of
the label number will be specified instead.
Description
Description