Measurement Parameters (Classification) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Measurement Parameters (Classification)

Specify the search measurement conditions and the judgement conditions for the measurement results.
1
In the Item Tab area, click [Measurement].
2
In the "Measurement condition" area,
specify a value for each item.
Setting item
Sub-pixel
Candidate level
3
When the setting has been changed,
click [Measure] in the "Detail" area to
verify whether measurements can be
made correctly.
4
Set up the judgement condition.
Note
• The values beside each item are measurement results of the displayed image. Take these values into
consideration to determine the upper and lower limit values.
Setting item
Position X
-99999.9999 to 99999.9999
Position Y
-99999.9999 to 99999.9999
Search
-180 to 180
angle
Correlation
0 to 100
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
When a check is placed at sub-pixel, the position information can be
• Checked
measured in units of sub-pixels. However, this requires more
• [Unchecked]
processing time.
Specify the threshold value with which to detect candidate points in a
0 to 100
rough search. Specify a smaller value when model search results are
[70]
unreliable.
Set value
Specify the range of X-axis shifting that is judged to be OK.
Specify the range of Y-axis shifting that is judged to be OK.
Specify the range of angles that are judged to be OK.
Specify the range of correlation values that are judged to be OK.
However, when the correlation value of the measurement result
is 0, the judgement result will be NG regardless of the lower limit
setting.
Description
Description
Classification
2
219

Hide quick links:

Advertisement

Table of Contents
loading