Settings (Di Branch); Timeout (Di Branch) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Settings (DI Branch)

Select the destination unit. Perform settings according to the information input in DI.
1
In the item tab area, click [Setting].
2
Click the DI input from the input signal list for which the branch destination is to be set up.
3
At "Destination unit", click [
the destination unit.
Important
• In order to avoid measurement processing looping, for the branch destination, set a processing unit number that
is after the [DI Branch].
• Make sure to set "End" at the last branch destination to indicate the end of the branch.
Reference: End (p.837)
• If the operation mode (FZ series) is set to [Multi-line random-trigger mode], DI inputs are handled differently as
follows.
Line 0: Conform to the statuses of DI0 and 1 inputs.
Line 1: Conform to the statuses of DI2 and 3 inputs.
• If the operation mode (FZ5-8/FZ5-11/FZ5-12) is set to [Multi-line random-trigger mode], DI inputs are
handled differently as follows.
Line 0: Conform to the statuses of DI0 and 1 inputs.
Line 1: Conform to the statuses of DI2 and 3 inputs.
4
Repeat the steps Reference:
units for other input signals.
Note
• Up to 32 (0 to 31) branch destinations can be set.
• The controller references the DI signal when the [DI Branch] measurement is executed.
5
Click [OK].
The settings are finalized.

Timeout (DI Branch)

Set the conditions under which the branching processing times out.
1
In the Item Tab area, click [Timeout].
FH/FZ5 Processing Item Function Reference Manual
] and set
2 (p.839) to Reference:
3 (p.839) and set the destination
5
839
DI Branch