Omron FH-3 Series Reference Manual page 755

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

4
If necessary, set each item in the
Advanced setting area.
Setting item
Stopping criteria for rotation
sampling
The number of points to
calculate error
Tolerance for error
The movement amount necessary for sampling measurement
Movement amount necessary for sampling measurement is calculated using the number of divided lines
(N) and the number divided lines (M).
: Measurement position
: Range of camera field of view
Parallel
movement
per 1 data
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
• [Only division point num]
• When error reaches
torelance
2 to 100
[2] to [10]
0 to 99999.999999
[1.000000]
: Reference position
: Center of the camera field of view
: Range of stage movement
Description
Select the end condition for rotational movement in this
calibration.
[Stopping criteria for rotation sampling], calculates error
within the range of [The number of points to calculate error].
Specify the upper limit value for the error detection.
: Valid range of the field of view
Number of movement points = N × M
Number of movement times = The number of
data items checked in [Calibration target].
When the parallel movement sampling by one
data is executed.
• Samples in every using camera.
• Calcurates the sampling moving amount as the
maximum moving range of the number of
movement point in parallel movement sampling
settings and the effective view range of camera.
• Reference position is the axis position of the
center view.
Reference position will be center of vision.
: Direction of movement
Vision Master Calibration
4
753