Measurement Results for Which Output Is Possible (Trend Monitor)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judge
Measurement
Warning
Maximum
Minimum
Deviation
Plus 3σ
Plus σ
Average
Minus σ
Minus 3σ
Measurement count
OK count
NG count
Warning count
Yield
FH/FZ5 Processing Item Function Reference Manual
Average of measurement values during period recorded - standard deviation of the
measurement values
Average of measurement values during period recorded - standard deviation of the
measurement values × 3
Measure count since the beginning of measurement
Number of measurements since starting to make measurements - NG count in number of
measurements
Number of NG occurrences within the measurement count
Warning count within the measurement count
OK count in number of measurements / Number of measurements since starting to make
measurements
Explanation of image to be displayed
Trend graph
Histogram
Character string
JG
Judgement result
DT
Latest measured value
WN
Existence of warning occurrence
MX
Max. measurement value during recording period
MN
Min. measurement value during recording period
DV
Standard deviation for measurement values during recording period
Average of measurement values during period recorded + standard
AP3
deviation of the measurement values × 3
Average of measurement values during period recorded + standard
AP1
deviation of the measurement values
AV
Average value for measurement values during recording period
Average of measurement values during period recorded - standard
AM1
deviation of the measurement values
Average of measurement values during period recorded - standard
AM3
deviation of the measurement values × 3
MC
Measure count since the beginning of measurement
Number of measurements since starting to make measurements - NG
OC
count in number of measurements
NC
Number of NG occurrences within the measurement count
WC
Warning count within the measurement count
OK count in number of measurements / Number of measurements since
YD
starting to make measurements
Description
Description
4
671
Trend Monitor