Omron FH-3 Series Reference Manual page 681

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Setting item
Condition
3
When [Only NG] is selected, click [...] to set up the expression.
The Setting Expression window is displayed.
4
Logging conditions are set using an expression.
Reference: Layout of Setting Expression Window (p.621)
5
After setting up the expression, click [OK].
The expression is confirmed.
6
Set up the judgement upper limit and the judgement lower limit for Judgement.
Setting item
Judgement condition
7
In the Format area, set save format.
Setting item
Format
Quality
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
• [None]
No images are saved.
Saves the images only if an NG occurs. If an NG occurs
downstream from the image conversion logging processing unit,
• Only NG
image conversion logging is not performed. Judgement uses the
measurement value at the point in time when measurement
processing is executed for image convert logging.
• All
All measured images are saved.
Set value
[Factory default]
-999999999.9999 to 999999999.9999
Set value
[Factory default]
• [Bitmap]
Select the image format to be saved.
• Jpeg
0 to 100
Specify the quality of the Jpeg image to be saved.
[100]
Description
Description
This is a judgement condition for the
expression. Set upper and lower limits for
judging as OK.
Description
Image Conversion Logging
4
679

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents