Setting item
• Corr. ascending
• [Corr. descending]
• X ascending
Sort condition
• X descending
• Y ascending
• Y descending
0 to 31
Search No.
[0]
3
When the setting has been changed,
click [Measure] in the "Detail" area to
verify whether measurements can be
made correctly.
4
Set up the judgement condition.
Note
• The values beside each item are measurement results of the displayed image. Take these values into
consideration to determine the upper and lower limit values.
Setting item
0 to 32
Count
[0] to [32]
-99999.9999 to 99999.9999
Measure X
[-99999.9999] to [99999.9999]
-99999.9999 to 99999.9999
Measure Y
[-99999.9999] to [99999.9999]
Search
-180 to 180
angle θ
[-180] to [180]
0 to 100
Correlation
[60] to [100]
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
Specify the method by which the search number is re-assigned.
When sorting based on the X and Y coordinates, the upper left is
the origin.
Specify which of the multiple detection results will be used as
measured results.
Set value
[Factory default]
Description
Description
Specify the number of detections that are judged to be OK.
Specify the range of X-axis shifting that is judged to be OK.
Specify the range of Y-axis shifting that is judged to be OK.
Specify the range of angles that are judged to be OK.
Specify the range of correlation values that are judged to
be OK. However, when the correlation value of the
measurement result is 0, the judgement result will be NG
regardless of the lower limit setting.