Key Points for Test Measurement and Adjustment (Machine Simulator)

The image specified in the Sub-image number in image display setting is displayed in the image display area.
Sub image.
0, 2 to 31
1
Key Points for Adjustment
Adjust the setting parameters referring to the following points.
The image is not compensated correctly
State
The corrected image is
completely different
The corrected image is
slightly different
Other
State
The reference unit number
is
<"None"> and
cannot be selected.
The reference unit number
does not change during
flow editing.

Measurement Results for Which Output Is Possible (Machine Simulator)

The following values can be output using processing items related to results output. It is also possible to refer to
measurement values from expressions and other processing units.
Measurement items
Judge
554
Machine Simulator
Explanation of image to be displayed
Measurement image (Same when a list of positions is displayed)
Input image
Parameter to be adjusted
Actual setting
Movement setting
Parameter to be adjusted
Machine setting
Machine setting
Character string
JG
Troubleshooting
The conditions for the actual coordinate system (origin position,
magnification, axis angle) may not be set correctly. Check for input
errors. In factory default, the real coordination system is same as
the camera coordination.
The current axis position may not be set correctly. Set this
condition when simulating a movement from other than the origin
return position. The current axis position is a parameter required
for accurate calculation of the travel distance of the actuator.
Troubleshooting
Check if the reference scene number is selected correctly.
Check if stage data processing items or robot data processing
items are registered in the selected reference scene.
The system is designed this way.
While a scene other than the current scene is referenced, the
reference unit number does not change according to the editing of
the flow. Change the flow so that the current scene will be
referenced, or set the reference unit number again.
Description
Judgment result
FH/FZ5 Processing Item Function Reference Manual