Plc Master Calibration - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

PLC Master Calibration

This processing item is specifically provided for calibration between the camera coordination system and the
control equipment coordination system.
In this processing item, the axis movement amount of the control equipment necessary for calibration can be set
freely.
If how to move the calibration mark has already been determined and it cannot be changed, use this processing
item. If it can be changed, we recommend you to use [Vision master calibration].
Important
• The calibration data created with this processing item can be referred from [Calibration Data Reference].
Unlike other calibration-related processing items, note that this processing item cannot use the calibration data on its
own.
• This function refers processing items, e.g. Stage Data or Robot Data, having external device information required the
calculation of movement distance. If you change those items, setting contents of PLC Master Calibration will change.
Rechecking settings is required.
Used in the Following Case
• When you want to position the FPD panel
PLC calculates the axis movement amount of stages required for calibration, and sets it to FH/FZ5.
FH/FZ5 Processing Item Function Reference Manual
Camera 1
Stage axis movement
Camera 0
amount
Stage
Axis control of stage
FH
Response
Trigger input
PLC
767

PLC Master Calibration

4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents