Settings Flow (Edge Positions)

Set the edge position with the following steps.
Necessary Steps
Start
Region Setting (Edge Position)
Measurement Parameters (Edge Position)
Settings completed
Test measurement
List of Edge Position Items
Item name
This item is used to set up the measurement area.
Region setting
Reference: Region Setting (Edge Position) (p.226)
Edge color
If the color of the edges to be detected is decided, specify the color.
(for color cameras
Reference: Edge Color Specification - For Color Cameras Only (Edge Position) (p.227)
only)
The edge position is registered as the reference when the region is set. Change as necessary.
Ref. setting
Reference: Reference Setting (Edge Positions) (p.227)
This item specifies the judgement condition for measurement results.
Measurement parameter can be changed as needed to address unstable measurement results.
Measurement
The displayed items depend on whether your camera is a color or monochrome camera. Normally,
the factory default value will be used.
Reference: Measurement Parameters (Edge Positions) (p.229)
This item can be changed if necessary. Normally, the factory default value may be used.
Output parameter
Select the measurement result coordinates and set how to handle the coordinates.
Reference: Output Parameters (Edge Position) (p.231)
FH/FZ5 Processing Item Function Reference Manual
Optional Steps
Edge Color Specification – For Color Cameras
Only (Edge Position)
Reference Setting (Edge Position)
Output Parameters (Edge Position)
Verify/Adjust results
Description
2